Description
The Kryo 360 Controlled Rate Freezer is used for pre freezing specimens before liquid nitrogen storage in applications such as:
- In Vitro Fertilization - human and animal
- Assisted Reproduction
- Ovarian Tissue freezing
- Embryo, Sperm and Oocyte freezing
- Animal husbandry
- Tissue preservation
- Cell line freezing
The Kryo 360 is a medium capacity controlled rate freezer: ideal for an IVF, ART or research laboratories.
Menu driven with fast cooling rates, controlled heating and multiple safety features.
Repeatability, consistent results and data recording are available from this reliable system used to freeze biological samples prior to long term cryo storage.
The equipment has multiple safety features, has data printing via its integral printer and allows multiple protocols. Controlled freezers give consistent results with validated high post thaw viability.
Also available in a non Medical Device version
Benefits:
- Simple to use through easy menus
- Safety records: ‘Run’ print out available
- User can define Horizontal or Vertical freezing
- Warming ramps are controlled
- Recording assists validation processes
- User changeable protocols allow technique updates
- PC failure accommodated – when running with software
- The -180ºC end temperature helps sample integrity during transfers
Features
Controlled heating
|
Chamber volume: 1.7 or 3.3 litres
|
Copes with temporary power/system outs
|
Lower temperature limit: -180 ºC
|
User calibration with hard copy
|
Cooling rates: -0.01 to -50 ºC/min
|
PC connection compatible
|
Controlled heating rates: 0.01 to 10 ºC/min
|
Time and date stamping
|
System controller: Planer's MRV controller
|
Programme preview before run
|
DeltaT Lite Software (Upgrades: V6/V7)
|
Control and data systems separated
|
Data storage and run are independent
|
Straw capacity: 60 x 0.25 ml or 45 x0.5ml
|
Vial or ampoule capacity: (30 or 60) x 2 ml
|
Straws in 15 positions radially located
|
Vials in 15 positions radially located |
Specifications
System Specifications |
Range |
+40°C to -180°C |
Heating rate |
0.01°C/min to 10°C/min |
Cooling rate |
-0.01°C/min to -50°C/min |
Controller accuracy |
±0.3 °C measured on a hold at 0 °C |
Storage temperature |
-10°C to +50°C |
Storage humidity |
5% to 95% relative humidity non-condensing |
Operating temperature |
5°C to 40°C |
Operating humidity |
5% to 90% relative humidity non-condensing |
Controller Specifications |
Dimensions |
80mm high x 220mm wide x 350mm deep |
Weight (approx.) |
2.6 kg |
Display |
240 x 64 LCD with CCFL backlight |
Printer |
320/640 dot thermal printer |
Keypad |
20 key membrane keypad |
Programmable Cooling Rate Range |
-0.01°C/min to -99.9°C/min |
Number of profiles |
10 |
Steps per profile |
32 |
Number of stored runs |
10 |
Chamber Specifications |
Weight (kg) |
14.4kg (1.7 Liter) or 14.7kg (3.3 Liter) |
Chamber dimensions |
1.7 L chamber: |
|
Internal 200mm x 150mm diameter External 450mm high x 300 mm wide x 420mm deep 3.3 L chamber: Internal 400mm x 150 mm diameter External 450mm high x 300mm wide x 420mm deep |
0.25 ml straws |
60 (1.7 L and 3.3 L chamber) |
0.5 ml straws |
45 (1.7 L and 3.3 L chamber) |
2 ml vials |
30 (1.7 L chamber) or 60 (3.3 L chamber) |
Power requirements (including MRV Controller) |
115V~ 50/60Hz 600VA / 230V~ 50/60Hz 600VA |
Additional Equipment Recommendation |
5 psi System |
System Pump - LNP4-C |
|
System Dewar - MVLAB 30 |
22 psi System |
System Cylinder - MVEUROCYL230SB |
|
Phase Separator - MVPHASE |
22 psi System (alternative) |
Vacuum Jacketed Pipe Work System |
|
Phase Separator - MVPHASE |