Description
The Kryo 560 is a medium sized controlled rate freezer with sample capacity sufficient for a busy laboratory.
Simple to program and easy to operate.
This rugged and reliable controlled rate freezer has a top opening chamber, a lid that is warmed to prevent freezing shut at cryogenic temperatures plus the unique forced laminar flow pattern ensuring excellent temperature control in all phases of the protocol. Planer’s MRV Controller system offers multiple protocol availability.
The -180ºC end temperature ensures sample integrity during transfer to storage at liquid nitrogen temperatures whilst the flexibility of the system, including protocol stage transition based on sample or chamber temperature or time, is ideal for the more demanding protocols associated with advanced cryo-preservation techniques.
Benefits:
- Freezes samples in bags, vials and straws
- Validation offered via Controller password controlled access on multiple user levels
- Menu driven controller, simple to operate
- Displays demand, sample and chamber temperatures
- Displays alphanumerically and graphically via an easy view display
- Trigger on sample, time or temperature
- Top opening chamber; lid is kept warm to prevent freezing shut at cryogenic temperatures
- Run print out via integral full view printer
- Time and date stamping, programme preview/verification before running
Features
- Chamber volume: 16 litres
- Capacity: 11 x 250/500/750ml bags, horizontally or vertically in chamber
- 48 x 25ml PALL bags
- Vial or ampoule capacity: 726 x 2ml in baskets
- Straw capacity: 608 x 2ml on canes (horizontal)
- Lower temperature limit: -180ºC
- Cooling rates: -0.01 to -50ºC/Min
- Controlled heating rates:0.01 to 10ºC/Min
- Controlled heating; start above ambient
- Data Printing (integral printer); Comms port for PC connection
- System controller: Planer's MRV
- System Pump: Planer's LNP4
- System Dewar: Chart LAB 30
- PC Software: Includes Planer's DeltaT Lite (Upgradable to Planer's DeltaT)
Specifications
System Specifications |
Range |
+30°C to -180°C |
Heating rate |
0.01°C/min to 10°C/min |
Cooling rate |
-0.01°C/min to -50°C/min |
Controller accuracy |
±(0.3 + 0.005 x TM)°C (TM = Temperature Magnitude) |
Storage temperature |
-10°C to +50°C |
Storage humidity |
5% to 95% relative humidity non-condensing |
Operating temperature |
5°C to 40°C |
Operating humidity |
5% to 90% relative humidity non-condensing |
Controller Specifications |
Dimensions |
80mm high x 220mm wide x 350mm deep |
Weight (approx.) |
2.6 kg |
Display |
240 x 64 LCD with CCFL backlight |
Printer |
320/640 dot thermal printer |
Keypad |
20 key membrane keypad |
Programmable Cooling Rate Range |
-0.01°C/min to -99.9°C/min |
Number of profiles |
10 |
Steps per profile |
32 |
Number of stored runs |
5 |
Chamber Specifications |
Weight (kg) |
23kg |
Capacity |
16 Liters |
Chamber dimensions |
350mm high x 230mm wide x 230mm deep |
0.25 ml straws |
2904 on canes or 456 on racks |
0.5 ml straws |
968 on canes or 456 on racks |
Vials |
784 x 1.0ml - 2.0ml or 244 x 5.0ml |
50ml blood bags |
22 |
250ml - 500ml blood bags |
11 |
PALL Bags |
22 |
Power requirements (including MRV Controller) |
115V~ 50/60Hz 1500VA / 230V~ 50/60Hz 15600VA |
Additional Equipment Recommendation |
5 psi System |
System Pump - LNP4-C |
|
System Dewar - MVLAB 30 or GDPB35 |
22 psi System |
System Cylinder - MVEUROCYL230SB |
|
Phase Separator - MVPHASE |
22 psi System (alternative) |
Vacuum Jacketed Pipe Work System |