Amerex HV-25, HV-50, HV-85, and HV-110 Portable Autoclaves

Amerex HV-25, HV-50, HV-85 & HV-110 Portable Autoclaves

PDFPrintEmail
Portable Autoclaves from Amerex have a space-saving design with lid opening upward. Programmable auto-start for initiating a cycle up to 1 week later. They are available in 25 liter, 50 liter, 85 liter and 110 liter sizes and are each protected by a 12-month warranty.
Request Quote
Download Brochure

Amerex HV-25, HV-50, HV-85 & HV-110 Portable Autoclaves

Description

Space-saving design with lid opening upward.

Programmable auto-start for initiating a cycle up to 1 week later.

Amerex HV Autoclave Control Panel

Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.

Automatic air purging by a microprocessor prevents over-pressurization during a cycle.

One-touch lever to easily open and close chamber lid.

Programmable rate of steam exhaust.

Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly.

In-process display shows status and progress of sterilization cycle.

Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.

Unique accessory: Floating sensor to monitor load temperature.

Sterilization timer is activated only when load temperature reaches set temperature.

Agar melting mode for rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up

Memory backup system retains user-programmed parameters even in case of power failure.

WARRANTY: Autoclaves are protected by a 12-month warranty.

HV-25 & HV-50 Specifications

Amerex HV-25 & HV-50 Autoclaves

MODELHV-25HV-50
TEMPERATURE
Operating Range 105ºC to 126ºC 105ºC to 135ºC
Display Range 128ºC 137ºC
Warming Range 45ºC to 60ºC
Agar Dissolution Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC
(programmable for up to 20 hours to prevent coagulation)
GAUGE PRESSURE
Operating Range 3 to 22 psi gauge (0.02 to 148MPa) 3 to 30 psi (0.02 to 0.206MPa)
Maximum Allowable 27 psi (0.186MPa) 38 psi (0.26MPa)
TIMER
Sterilization 1 to 250 minutes
Delayed Auto-start Program autoclave to start 1 minute to 7 days later
DIMENSIONS
Overall (W x D x H) 19.0" x 18.0" x 37.4"
(48 cm x 46 cm x 95 cm)
20" x 21" x 41"
(51 cm x 53 cm x 104 cm)
Chamber
(Diameter x Height)
25 liters
9.4" x 21.6" (24 cm x 55 cm)
50 liters
11.8" x 28.0" (30 cm x 71 cm)
SAFETY DEVICES Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
PROGRAMS
1. For agar Heating >> Sterilization >> Exhaust (from no exhaust to slow, programmable) >> Warming >> Completion
2. For liquids Heating >> Sterilization >> Exhaust (from no exhaust to slow, programmable) >> Completion
3. For solids Heating >> Sterilization >> Exhaust (fast, default) >> Completion
4. For melting agar or for faster start-up Rapid melting at 60°C to 100°C (temperature and time programmable) >> Maintain at 45°C to 60°C (temperature programmable) >> Completion
ACCESSORIES
Stainless steel Mesh wire baskets, buckets (pails), and round test tube racks
Factory or field installed Floating (load) sensor, digital printer, and data logger
POWER
Source 120V, 50/60 Hz (220V/240V available)
Consumption 1500 watts (1500VA) 2000 watts (2000VA)
SHIPPING WEIGHT 160 lb (73 kg) 180 lb (82 kg)

HV-85 & HV-110 Specifications

Amerex HV-85 & HV-110 Autoclave Specifications

 

MODELHV-85HV-110
TEMPERATURE
Operating Range 105ºC to 135ºC
Display Range 137ºC
Warming Range 45ºC to 60ºC
Agar Dissolution Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC
(programmable for up to 20 hours to prevent coagulations)
GAUGE PRESSURE
Operating Range 3 to 30 psi (0.021 to 0.206MPa)
Maximum Allowable 38 psi ( 0.26MPa)
TIMER
Sterilization 1 to 250 minutes
Delayed Auto-start Program autoclave to start 1 minute to 7 days later
DIMENSIONS
Overall (W x D x H) 26.0" x 25.6" x 39.4"
(66 cm x 65 cm x 100 cm)
26.0" x 25.6" x 46.5"
(66 cm x 65 cm x 118 cm)
Chamber
(Diameter x Height)
85 liters
16.5" x 24.2" (42.0 cm x 61.5 cm)
110 liters
16.5" x 31.3" (42.0 cm x 79.5 cm)
SAFETY DEVICES Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
PROGRAMS
1. For agar Heating >> Sterilization >> Exhaust (from no exhaust to slow, programmable) >> Warming >> Completion
2. For liquids Heating >> Sterilization >> Exhaust (from no exhaust to slow, programmable) >> Completion
3. For solids Heating >> Sterilization >> Exhaust (fast, default) >> Completion
4. For melting agar or for faster start-up Rapid melting at 60°C to 100°C (temperature and time programmable) >> Maintain at 45°C to 60°C (temperature programmable) >> Completion
ACCESSORIES
Stainless steel Mesh wire baskets, buckets (pails), and round test tube rack
Factory or field installed Floating (load) sensor, digital printer, and data logger
POWER
Source 208V/220V/240V, 50/60 Hz, single phase
Consumption 3000 watts (3000VA) 4000 watts (4000VA)
SHIPPING WEIGHT 282 lb (128 kg) 308 lb (140 kg)

 